Low Differential Pressure Switch

The F-5300 Series Low Differential Pressure Switches, designed for a minimal difference between the “ON” and “OFF” pressure, interface from pressure to electric control circuits.

Delivery time: 2 - 4 weeks
Contact us for shorter delivery times Art.-Nr.: N/A Categories: ,

The switches are adjustable from 0.5 to 100 PSI with a maximum signal pressure of 100 PSI. They have three electrical terminals: Normally Open, Normally Closed, and Common. 4 AMP switches are standard; a 0.1 AMP switch is also available. Four mounting styles are available: Flush Mount, Manifold Mount, Panel Mount, and Pipe Thread Mount. The Flush Mount has 0.125″ diameter mounting holes for mounting on a flat surface. The Manifold Mount is designed to mount directly on pneumatic circuit boards or manifold subplates; a Buna-N o-ring is supplied. The Panel Mount has a unique thread that goes from 1/8-27 tapered pipe thread to 1/8-27 straight pipe thread; a mounting nut is supplied. The Pipe Thread Mount has 1/8-27 tapered pipe threads. The switches are provided with a B80 Barb, 10-32 UNF Barbed Fitting, for 1/16″ I.D. tubing unless otherwise requested.

FEATURES

•Low Cost
•Subminiature Size
•High-Pressure Adjustment
•Low Differential
•Fast Response

SPECIFICATIONS

Electrical Specifications
Switch Action: Single pole, double throw
Electrical Rating: 4 AMP is standard; no selection number is required. 0.1 AMP is also available.
Electrical Switch: UL Approved, (UL# E12252)
Electrical Connections: 0.110″ quick-connect terminal
Mechanical Specifications
Operating Speed: Activate or release in 25 milliseconds
Signal Pressure: 6.89 bar (100 PSI maximum)
Adjustment Range: 0.34 to 6.89 bar (0.5 to 100 PSI) +/- 0.5 tolerance on the initial starting pressure
Temperature Limits: 40 to 120 °F (5 to 48 °C)

MATERIALS

Housing: Polysulfone
Diaphragm: Polyurethane
Spring: Stainless Steel or Music Wire

PORT CONNECTIONS

10-32 female threads, furnished with barbed fitting:
B80: 10-32 UNF Barbed Fitting for Ø1.6 mm (1/16″) I.D. tubing
B85: 10-32 UNF Barbed Fitting for Ø3.2 mm (1/8″) I.D. tubing
B86: 10-32 UNF Barbed Fitting for Ø4.3 mm (0.170″) I.D. tubing

MOUNTING

Flush Mount: 0.125″ diameter mounting hole; use No. 4 self-tapping or 5-40 screw
Manifold Mount: Two 0.125″ diameter mounting holes; use No. 4 self-tapping or 5-40 screw (A Buna-N o-ring is supplied)
Panel Mount: External 1/8-27 NPT to 1/8-27 NPS, internal threads are 10-32 UNF. Ø11.11 mm (7/16″) diameter mounting hole is required. (A mounting nut is supplied)
Pipe Thread Mount: 1/8-27 male tapered pipe threads with 10-32 UNF female internal threads

Adjustment Range

100 – Adjustable 0.03 – 6.9 bar (0.5 – 100 PSI), 15 – Adjustable 0.03 – 1 bar (0.5 – 15 PSI), 30 – Adjustable 0.03 – 2.1 bar (0.5 – 30 PSI), 60 – Adjustable 0.03 – 4.1 bar (0.5 – 60 PSI)

Mounting Style

FM – Flush Mount, MM – Manifold Mount, PM – Panel Mount, PT- Pipe Thread Mount

Port Connection

B80 – Ø2.65 mm barb for Ø1.6 mm I.D. tubing, B85 – Ø4.75 mm barb for Ø3.2 mm I.D. tubing, B86 – Ø5.60 mm barb for Ø4.3 mm I.D. tubing

Switch Selection

.1B – 0.1 AMP, 4A – 4 AMP

Drawings

3D-Files

Please contact us for other formats.

Catalogs